ECG/EKG Tester


The WhaleTeq ECG test solution is a comprehensive tool designed specifically for the industry and R&D testing. We strive to provide the intelligent solution of combining a single channel test system, multichannel test system, and common mode rejection ratio test, our ECG test solution puts the completed testing and verification tool in your hands. The ECG test solution integrated the regulatory required testing (IEC 60601-2-25, -2-27, -2-47; AAMI/ANSI EC11, EC13, EC38, EC57; China YY1079, YY1139, YY0782, YY0885 etc.) within one system providing you the confidence and convenience for quality assurance.

The ECG test solution is equipped with mV accuracy that is ten times more accurate of the required standards for different sources. It is not merely an ECG simulator, but a must-have tool for your R&D testing and Performance testing to meeting ALL required international standards.


Watch the video for quick and thorough understanding about WhaleTeq ECG Test Solution
 


On top of the ECG test solution built for R&D and QA purpose, WhaleTeq also provides customized production line testing services for your specific needs. For more information, please contact our customer service representative: service@whaleteq.com 
 



See how WhaleTeq testing equipment cover the required standard tests

Need more details? Here are the comprehensive cross reference tables to illustrate the full coverage and capacity of our testing equipment for the IEC 60601 requirement.


Open All | Close all BB: Breakout Box. FG: Function Generator
SECG MECG CMRR Box ECG BB CMRR BB FG
201.12.1.101.2 Requirements for amplitude measurements x x
201.12.1.101.3.1 Requirements for absolute interval and wave duration measurements x x
201.12.1.101.3.2 Requirements for interval measurements on biological ECGS x x
201.12.4.101 Indication of inoperable ELECTROCARDIOGRAPH x x
201.12.4.102.3.2 Goldberger and Wilson LEADS x x
201.12.4.102.4 Recovery time x x
201.12.4.103 Input impedance x x
201.12.4.105.1 COMMON MODE REJECTION x x x
201.12.4.105.2 Overload tolerance x x
201.12.4.105.3 FILTERS (including line frequency interference FILTERS) x x
201.12.4.106.1 NOISE level x x
201.12.4.106.2 CHANNEL crosstalk x x
201.12.4.107.1.1.1 High frequency response x x
201.12.4.107.1.1.2 Low frequency (impulse) response x x
201.12.4.107.1.2 Test with calibration ECGS x x
201.12.4.107.2 Linearity and dynamic range x x
201.12.4.108.3.2 Recording speed x x
201.12.4.109 Use with cardiac pacemakers x x

. SECG MECG CMRR Box ECG BB CMRR BB FG
201.12.1.101.1 Accuracy of signal reproduction x x
201.12.1.101.2 Input dynamic range and differential offset voltage x x
201.12.1.101.3 Input impedance x x
201.12.1.101.4 Input NOISE x x
201.12.1.101.5 Multichannel crosstalk x x
201.12.1.101.6 GAIN control and stability x x
201.12.1.101.7 Sweep speed x x
201.12.1.101.8 Frequency and impulse response x x
201.12.1.101.9 GAIN INDICATOR x x
201.12.1.101.10 Common mode rejection x x x
201.12.1.101.11 Baseline reset x x
201.12.1.101.12 Pacemaker pulse display capability x x
201.12.1.101.13 Rejection of pacemaker pulses x x
201.12.1.101.14 Synchronizing pulse for cardioversion x x
201.12.1.101.15 Heart rate range, accuracy, and QRS detection range x x
201.12.1.101.16 Channel height and aspect ratio x x
201.12.1.101.17 Tall T-wave rejection capability x x

. SECG MECG CMRR Box ECG BB CMRR BB FG
201.12.1.101.1.2.1 The accuracy of QRS detection x x
201.12.1.101.1.2.2 The accuracy of heart rate measurements x x
201.12.1.101.1.2.3 The accuracy of VEB detection x x
201.12.1.101.1.2.4 Claime to detect ventricular flutter or fibrillation (VF) x x
201.12.1.101.1.2.5 Claimed to detect supraventricular ectopic beats, or atrial flutter or fibrillation (AF), claimed to measure ST SEGMENT deviations or to detect ST SEGMENT changes x x
201.12.1.101.1.5.1 Required statistics x x
201.12.1.101.1.5.2 Requirements for all arrhythmia algorithms x x
201.12.1.101.1.5.3 Requirements for algorithms with optional capabilities x x
201.12.1.101.1.6 Simulated test patterns x x
201.12.1.101.2.1 Use of standard databases x x
201.12.1.101.2.2 Use of annotation files x x
201.12.1.101.2.3 Beat-by-beat comparison x x
201.12.1.101.2.3.1 General description x x
201.12.1.101.2.3.2 Method for beat-by-beat comparison x x
201.12.1.101.2.3.3 Heart rate, and heart rate or RR interval variability x x
201.12.1.101.2.3.3.1 Heart rate measurement x x
201.12.1.101.2.3.3.2 Heart rate variability or RR interval variability measurement test Patterns x x
201.12.1.101.2.4 Run-by-run comparison x x
201.12.1.101.2.4.1 General description x x
201.12.1.101.2.4.2 Terms and symbols x x
201.12.1.101.2.4.3 Run sensitivity summary matrix x x
201.12.1.101.2.4.4 Run positive predictivity summary matrix x x
201.12.1.101.2.5 VF and AF comparisons x x
201.12.1.101.3 Physician report – minimum requirements x x
201.12.1.101.3.1 Heart rate x x
201.12.1.101.3.2 Supraventricular ectopy x x
201.12.1.101.3.3 Ventricular ectopy x x
201.12.1.101.3.4 Bradycardia data x x
201.12.1.101.3.5 PAUSES x x
201.12.1.101.3.6 ST SEGMENT shifts x x
201.12.1.101.3.7 ECG hard copy x x
201.12.4.4 Incorrect output x x
201.12.4.4.101 Linearity and dynamic range x x
201.12.4.4.102 Input impedance x x
201.12.4.4.103 Common mode rejection x x x
201.12.4.4.104 GAIN accuracy x x
201.12.4.4.105 GAIN stability x x
201.12.4.4.106 System noise x x
201.12.4.4.107 Multichannel crosstalk x x
201.12.4.4.108 Frequency response x x
201.12.4.4.109 Function in the presence of pacemaker pulses x x
201.12.4.4.110 Timing accuracy x x
201.12.4.4.111 GAIN settings and switching x x
201.12.4.4.112 Temporal alignment x x


Select your WhaleTeq testing equipment

You can depend on our WhaleTeq testing equipment for the complete and compliant tests to fulfill the regulatory requirements. Click on the specific model for more product description or let us help you choose the right product for you; contact our customer service representative to get more details.

Model Description Standard Links / Downloads Inquiry
ECG Set ECG SET
- WhaleTeq ECG Set is a combination of SECG4.0, MECG2.0 and CMRR2.0 and two breakout boxes.
- Please refer to individual ECG equipment introduction or visit ECG homepage to know more about our product.
See above. Product Brochure
Quote request
SECG 4.0 Single Channel ECG Test System
- Performance tester for 1/3/5/12 lead ECG device
- Built-in test circuits as defined in ECG standards
- Good shielding and grounding designs allow for higher accuracy
- Adjustable DC offset and pacemaker signals output
- Load and replay your own ECG files

IEC 60601-2-25:2011
IEC 60601-2-27:2005
IEC 60601-2-27:2011
IEC 60601-2-47:2012
IEC 60601-2-51:2003
AAMI EC 11
AAMI EC 13

Product Brochure
User manual
Software
Quote request
SECG - Assistant Software SECG-Assistant Software
- Complement software for WhaleTeq/MEDTEQ SECG4.0
- Save time in conducting ECG performance tests
- Less burden in reading particular standards
- Preset parameter settings for each required stardards
- "Remark" to provide quick reference to standard test precedures and requirements
IEC 60601-2-25:2011
IEC 60601-2-27:2011
IEC 60601-2-47:2012
YY 1079-2008
YY 1139-2013
YY 0782-2010
JJG760-2003
IEC60601-2-26:2012
Learn More
Software
Quote request
MECG 2.0 Multichannel ECG Test System
- ECG database generator for Diagnostic and Ambulatory ECG
- Support IEC60601-2-25, -2-47 and AAMI EC57 database tests
- Embedded CAL, ANE, Biological, NST waveforms
- Allows to upload and playback AHA, MIT, and CU format directly

IEC 60601-2-25:2011
IEC 60601-2-47:2012
IEC 60601-2-51:2003
AAMI EC57

Product Brochure
User manual
Software
Quote request
CMRR 2.0 Common Mode Rejection Ratio Tester
- Compact design
- Test circuits meeting the standards' requirements

- Superior shielding and grounding designs
- Custom built transformer to supply the required 20Vrms
- Double shield construction built 

IEC 60601-2-25:2011
IEC 60601-2-27:2005
IEC 60601-2-27:2011
IEC 60601-2-47:2012
IEC 60601-2-51:2003
AAMI EC 11
AAMI EC13

Product Brochure
User manual
Quote request
CMRR 3.0 ECG Common Mode Rejection Ratio Tester
- Designed for ECG, Patient Monitor, Holter and EEG CMRR and system noise testing. 
- Supported standard: IEC 60601-2-25/27/47/26, YY1079/1139/0782/0885, ANSI/AAMI EC11/13. 
Superior shielding and grounding designs allow wider CMRR measurement.
IEC 60601-2-25:2011
IEC 60601-2-27:2011
IEC 60601-2-47:2012
IEC 60601-2-26:2012
China YY 0782-2010
China YY 0885-2013
China YY 1079-2008
China YY 1139-2013
AAMI/ANSI EC11
AAMI/ANSI EC13
Product Brochure
User manual
Software
Quote request
HFCN High Frequency Coupling Network
- Conveniently prebuilt test fixture for electrosurgery interference
- Built-in skin impedance 51k/47nF
- Simulate 1mV ECG signal for ESIS
- Power rating >300W; Resistor inductance <5μH
IEC 60601-2-25/-2-27/-2-49:2011 Clause 202.6.2.101 
China YY1079:2008 Clause 5.2.8.13
AAMI EC13:2002 Clause 5.2.9.14 
User manual
Quote request