DFS360 Defibrillator / AED Production Line Tester

Designed specifically for Defibrillator/AED production line application and solves the need to integrate most devices. Withstand more intense defibrillation shocks at a long duration. Display defibrillation shock waveform, energy joule numbers, as well as characteristics points at the same time. Supporting various ECG waveforms with customized user-defined data or clinical signals. Also, SDK provided to enhance AED manufacturing automation. Dual loading model (DFS360D) to withstand more intense defibrillation shocks.

Overview
Specification
Ordering information
  • Display defibrillation shock waveform, energy joule numbers, as well as characteristics points at the same time
  • Adult and child modes, along with 4 μs sampling rate raw data, to achieve high accuracy
  • Applicable to all AEDs and defibrillators production line environment
  • Thorough characteristics points of waveform & automatic calculated energy values
  • The characteristics points data & waveform display can be saved and exported
  • SDK provided to enhance AED manufacturing automation
  • Dual loading model (DFS360D) to withstand more intense defibrillation shocks (at 15 seconds interval)
  • Supporting various ECG waveforms with optional user-defined patterns or clinical signals (up to 10 sets) 
  • Over heat warning and function protection
  • USB cable for continuous and sustainable power supply
  • The optional paddle box set has outstanding electrical conductivity and mechanical characteristics. The conductive gel drainage grooves are designed for easy cleaning

- AED Testing Scenario

- Defibrillator Testing Scenario

 

Energy Measurement Specifications

Items Specifications
Maximum Energy Range : Up to 600J
Voltage

Range : Up to 3000V

Accuracy : 1% ± 1V for 450V ~ 3000V & -450V ~ -3000V;

                  1% ± 2V for -450V ~ 450V

Load Resistance Resistance : 50Ω
Pulse Width

Range : 1.0 to 48.0 ms

Accuracy : ±0.05 ms

Maximum Average Power

DFS360 : 12W, equivalent to 1 defib pulse of 360J every 30 seconds

DFS360D : 24W, equivalent to 1 defib pulse of 360J every 15 seconds

 

ECG Signal Specifications

Items Specifications
Ventricular Fibrillation - Coarse Vp-p = 3mV
Ventricular Fibrillation - Fine

Vp-p = 0.5mV

Ventricular Tachycardia (≒180BPM)

Vp-p = 3mV

Ventricular Tachycardia Plus (≒234BPM) Vp-p = 3mV
Atrial Fibrillation

Vp-p = 1.2mV

Asystole

Vp-p = 0.03mV

User defined pattern

(Max. 5K Sample Rate)

Up to 10 sets with 100 seconds max each set

 

General Specifications

Items Specifications
Temperature

Operating : 0°C to 50°C (32°F to 122°F)

Storage : -20 °C to +60°C (-4°F to +140°F)

Humidity 10% to 90% non-condensing
Communications

USB

Type C connector

Operation Modes Remote (PC Software via API and SDK)
Power

 USB 3.0 Bus Power

Mechanical

Housing : ABS Plastic

Size (L x W x H) : 19.0cm x 12.5cm x 6.0cm
Weight : DFS360 : 665g

              DFS360D : 815g

 

Compliance Specifications

Items Specifications
Safety Standards CE : IEC / EN 61010 - 1 : 2010 + A1 : 2016; Pollution degree 2
61010 - 2 - 030 : 2017
Electromagnetic Compatibility Standards (EMC)

CE : EN61326 -1

FCC : EMC P15B

 

Specifications are subject to change without prior notice.

DFS360 Test System

Model No. Image Description

300-DFS36S

DFS360 Defibrillator Production Line Tester Main Unit

N61-0210033

Compact Splicing Connector

K27-1800304

USB Transfer Cable A to C (M to M), 1.8 meter

 

DFS360D Test System

Model No. Image Description

300-DFS36D

DFS360D Defibrillator Production Line Tester (Dual) Main Unit

N61-0210033

Compact Splicing Connector

K27-1800304

USB Transfer Cable A to C (M to M), 1.8 meter

 

Optional DFS360/DFS360D Paddle Box Set

Model No. Image Description

300-DFPDOCK

DFS Tester Docking Base for Defibrillator

300-DFPBRDG

DFS Tester Bridge to Docking Base for Defibrillator

E13-070P101

DFS Tester Defibrillation Receiving Plate

 

Optional Software Add-On Pack

Model No. Description

H40-DF00001

User-defined ECG patterns or clinical signals (10 sets) for DFS360/ DFS360D

 

Optional Calibration Service and Warranty Extension

Model No. Description
C3 Provides (3) years of calibration service coverage. WhaleTeq equipment can be calibrated to original performance on the basis of (1) year interval.
R3

Extend the limited warranty from (1) year to (3) years.

 